Poult. Sci.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Poult Sci 2008. 87:577-587. doi:10.3382/ps.2007-00167
© 2008 Poultry Science Association
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yeh, L.-C.
Right arrow Articles by Chou, C.-C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yeh, L.-C.
Right arrow Articles by Chou, C.-C.

PROCESSING, PRODUCTS, AND FOOD SAFETY

Development of Amoxicillin Enzyme-Linked Immunosorbent Assay and Measurements of Tissue Amoxicillin Concentrations in a Pigeon Microdialysis Model

L.-C. Yeh*,{dagger}, W.-M. Lee*, B.-W. Koh*, J. P. Chan*, C.-H. Liu{dagger}, J.-P. Kao* and C.-C. Chou*,1

* Veterinary Medicine Teaching Hospital and Department of Veterinary Medicine, College of Veterinary Medicine, National Chung-Hsing University, Taichung, Taiwan, 402; and {dagger} The Branch Institute of Animal Drug Inspection, Animal Health Research Institute, Council of Agriculture, Executive Yuan, Taiwan, 350

1 Corresponding author: ccchou{at}nchu.edu.tw

A sensitive ELISA was developed for the detection of amoxicillin (AMX) in serum, urine, and milk. The ELISA used an indirect competitive method produced by coating the plate with ovalbumin conjugated with AMX hapten. Antibodies against AMX-BSA were detected by a goat-antirabbit antibody conjugated with peroxidase. Calibration standard curves ranged from 1.28 ng/mL to 20 µ g/mL [IC50 (inhibition concentration 50%) = 100 ng/mL], and the limits of detection were 1.3, 2.7, and 4.8 ng/mL for urine, milk, and serum, respectively. The intra- and interassay variations were less than 4 and 9.6%. The antibody produced against AMX cross-reacted highly with penicillin G (77%); cross-reacted moderately with ampicillin, oxacillin, and cloxacillin (56.9, 51.4, and 48.8%, respectively); but was considered non-cross-reactive with dicloxacillin (7.4%), cefadroxil (<1%), and cefazolin (<1%). Concentrations of AMX were measured simultaneously in venous blood and muscles by using the developed AMX ELISA in an in vivo microdialysis model designed for pigeons. Following i.m. injection (25 mg/kg), AMX attained a peak blood level of 4.74 ±0.30 µ g/mL and decreased with a half-life of 2.38 ±0.16 h. In contrast, measurements in pectoral and femoral muscles exhibited delayed appearances, reduced peak concentrations, and prolonged half-lives of 4.07 ±0.48 (pectoral) and 3.01 ±0.26 (femoral) that were significantly different from each other and those in the blood (P < 0.05). Blood protein binding was calculated to be 27.9 ±5.7%. This study demonstrated the semiquantitative application of a selective AMX ELISA in the first microdialysis procedure for continuous monitoring of drug levels in specific tissues of pigeons and maybe useful for related studies in other poultry species.

Key Words: pigeon microdialysis • amoxicillin • enzyme-linked immunosorbent assay







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by the Poultry Science Association.